Noise2Quality: Non-Reference, Pixel-Wise Assessment of Low Dose CT Image Quality

1Saratoga High School, 2Stanford University

Abstract

CT image quality is reliant on radiation dose, as low dose CT (LDCT) scans contain increased noise in images. This compromises the diagnostic performance on such scans. Therefore, it is desirable to perform Image Quality Assessment (IQA) prior to diagnostic use of CT scans. Often, image quality is assessed with full-reference methods, where a LDCT is algorithmically compared against its full dose counterpart. However due to health concerns, acquiring full dose CT scans is challenging and not desirable. As an alternative, non-reference IQA (NR-IQA) can be performed. Moreover, IQA at the pixel level is important, as most IQA methods only provide a global assessment, which means localized regions of interest cannot be specifically assessed. A solution for localized-IQA is to produce visually-interpretable quality maps. Deep learning methods could be employed by leveraging computer vision techniques, such as Self-Supervised learning (SSL). In this work, we propose Noise2Quality (N2Q)---a novel self-supervised, non-reference, pixel-wise image quality assessment model to predict IQA maps from LDCTs. Self-supervised dose level prediction as an auxiliary task further improves the model performance. Our experimental evaluation both qualitatively and quantitatively demonstrates the effectiveness of the model in accurately predicting IQA maps over various baselines.

This paper was accepted to SPIE Medical Imaging 2022. The paper was presented in February at the conference in San Diego and is availabe in the proceedings. Here are some photos of us presenting.

Methods

  • Our model performs localized CT image quality assessment using a deep learning method.
  • We predict SSIM quality maps based on an input low-dose CT image. We calculate SSIM maps using the full-dose reference for our training set. We train the model to map LDCT to quality maps.
  • We leverage an innovate self-supervised auxiliary task of predicting the dose level of the LDCT. This helps the network learn additional relevant features while preventing overfitting and improving generalization.
  • We use a standard U-Net architecture as our backbone which can be replaced with improved models. Our loss function contains two components: the MSE loss for SSIM maps and the auxiliary task loss for dose level prediction.
  • Visualizations and Metrics

    Poster

    BibTeX

    @inproceedings{haque2022noise2quality,
          title={Noise2Quality: non-reference, pixel-wise assessment of low dose CT image quality},
          author={Haque, Ayaan and Wang, Adam S and Imran, AAZ},
          booktitle={Medical Imaging 2022: Image Perception, Observer Performance, and Technology Assessment},
          volume={12035},
          year={2022},
          organization={SPIE}
        }